Cold Plasma Inverter Split Air Conditioning Specifications
|
Model
|
ECO918SD
|
ECO1218SD
|
ECO1818SD
|
ECO2418SD
|
|
Power supply
|
Ph-V-Hz
|
1, 220-240V~, 50Hz
|
1, 220-240V~, 50Hz
|
1, 220-240V~, 50Hz
|
1, 220-240V~, 50Hz
|
|
Fed to
|
Indoor
|
Indoor
|
Indoor
|
Indoor
|
|
Cooling
|
Capacity
|
kW
|
2.7 (0.45~3.23)
|
3.62 (0.6~3.96)
|
5.4 (1.05~6.5)
|
6.74 (1.5~7.0)
|
|
Input Power
|
kW
|
0.78 (0.2~1.35)
|
1.06 (0.22~1.45)
|
1.6 (0.36~2.5)
|
2.07 (0.35~2.5)
|
|
EER
|
W/W
|
3.46
|
3.42
|
3.31
|
3.26
|
|
Heating
|
Capacity
|
kW
|
3.52 (0.45~4.1)
|
4.1 (0.6~5.13)
|
5.8 (1.0~7.0)
|
7.0 (1.2~7.8)
|
|
Input Power
|
kW
|
0.95 (0.2~1.45)
|
1.11 (0.22~1.55)
|
1.57 (0.35~2.6)
|
1.93 (0.35~2.7)
|
|
COP
|
W/W
|
3.7
|
3.69
|
3.69
|
3.62
|
|
Starting Current
|
A
|
5.1
|
6.7
|
10
|
12
|
|
Max. Current
|
A
|
6.88
|
7.32
|
9.76
|
11.98
|
|
Indoor noise level (Hi/Mi/Lo)
|
dB(A)
|
41/38/30/24
|
42/39/31/24
|
45/40/37/32
|
46/42/37/32
|
|
Indoor unit
|
Net Dimension (W*H*D)
|
mm
|
770*283*201
|
770*283*201
|
865*305*215
|
1008*319*221
|
|
Net/Gross weight
|
Kg
|
8/11
|
9/12
|
12/16
|
15/20
|
|
Outdoor noise level
|
dB(A)
|
51
|
53
|
54
|
54
|
|
Outdoor unit
|
Net Dimension(W*H*D)
|
mm
|
658*550*275
|
658*550*275
|
890*610*370
|
955*700*396
|
|
Net/Gross weight
|
Kg
|
28/32
|
30/34
|
52/57
|
52/57
|
|
Refrigerant type R410A @ 5 metres
|
g
|
700
|
960
|
1100
|
1400
|
|
Refrigerant piping
|
Liquid side/ Gas side
|
mm(inch)
|
6.35(1/4)/9.52(3/8)
|
6.35(1/4)/9.52(3/8)
|
6.35(1/4)/12.7(1/2)
|
6.35(1/4)/12.7(1/2)
|
|
Max. refrigerant pipe length
|
m
|
15
|
20
|
25
|
25
|
|
Max. Elevation
|
m
|
10
|
10
|
10
|
10
|
|
Dehumidification
|
litres/h
|
1.0
|
1.2
|
2.0
|
2.0
|
|
Energy Rating (Cooling / Heating)
|
A/A
|
A/A
|
A/A
|
A/A
|
|
Fuse Rating
|
A
|
13
|
13
|
20
|
32
|
|
Interconnecting Cable
|
3C+E
|
3C+E
|
3C+E
|
3C+E
|
|
Ambient Temperature (Heating)
|
°C
|
-15 ~ 48
|
-15 ~ 48
|
-15 ~ 48
|
-15 ~ 48
|
|
Ambient Temperature (Cooling)
|
°C
|
10~48
|
10~48
|
10~48
|
10~48
|
|
Operation temp
|
°C
|
16~30
|
16~30
|
16~30
|
16~30
|
|
Annual Energy Consumption (over 500 hours)
|
Kw
|
390
|
530
|
800
|
1035
|
Note: Due to our policy of innovation some specifications may be changed without notification.
These units contain a gas governed by F-Gas regulations. The gas must be handled by qualified F-Gas engineers.
|